1 min read

Asia Powercom APLI-1000 and APLI-2000 UPS with Long Backup and 20A Charging Current

AsiaPowercom logoAsia Powercom, global leader in power protection – a division of Powercom Co. Ltd, launched APLI-1000 and APLI-2000 UPS. These products provide protection against short circuit and overload.  It also comes enabled with auto restart while AC is recovering. It is enabled with fully digitized microprocessor and off mode battery charging.

Key Features

  • Line interactive design.
  • 20A super battery charger.
  • Fully digitized microprocessor controlled.
  • Cold start function (DC power on).
  • AVR input voltage Range 140V- 300V.
  • Short circuit and overload protection.
  • Off mode Battery charging.
  • Auto restart while AC is recovering

Tejas  ShethCountry Manager at Asia Powercom,  said “We have designed APLI-1000 and APLI-2000  in such a way that it gives users protection against short circuit and overload. It is also enabled with 20A super battery charger to ensure that users get uninterrupted power supply. Partners in the market are aware that Asia Powercom products deliver on par to what they claim.

Technical Specifications

Model

APLI-1000

APLI-2000

Input Voltage

Frequency Range

AVR

Connection (1.5m wire)

230V

45-55Hz

140V-300V

3 pin, 10A plug

 

 

230V

45-55Hz

140V-300V

3 pin, 10A plug

Output Voltage on mains

Frequency on mains

Voltage on Battery

Waveform

Power Factor Lagging

Sockets

230V +10% -15%

Follows input

230V ±10%

Quasi sinewave

0.6

4 x universal socket

230V +10% -15%

Follows input

230V ±10%

Quasi sinewave

0.6

4 x universal sockets

Protection Input Protection

O/P short circuit

O/P overload shutdown

MCB / Fuse

UPS shutdown immediately

110% for 3 min, 150% for 10 Sec

 

MCB / Fuse

UPS shutdown immediately

110% for 3 min, 150% for 10 Sec

Transfer Time Mains to inverter 4 – 8 ms 4 – 8 ms
Battery DC Bus

Internal Battery

Battery charge current

Protection

Typical Recharging time

12V

Nil

5/10/20 A selectable

Auto discharge protection

10 – 12 hours

24V

Nil

5/10/20 A selectable

Auto discharge protection

10 – 12 hours

Indications Line Mode

Inverter Mode

Fault

Green LED

Yellow Flashing

Red LED

Green LED

Yellow Flashing

Red LED

Alarm Battery Low

Overload

Ambient operation

Rapid beeping sound (1 sec)

Continuos beeping sound

0-40°C, 0-95% humidity non condensing, 3500 meter max.

Environment Audible noise

Storage Condition

<40 DbA (1 meter from surface)

15,000 meter max. Elevation

Physical Weight

Dimension – DxWxH (mm)

8 Kgs.

350 x 146 x 160

10 Kgs.

350 x 146 x 160